Shade
Compare reflected light on a black-to-white scale. This is a lightness check, rather than a full colour measurement.
Product viewManufacturer images · Select a thumbnail to explore the instrument and measurement modes.
Compare lightness, assess hiding power and investigate surface contamination with one portable instrument. Get practical advice on the testing method and accessories from Novasys in Australia.
Ask Novasys about suitability, test materials and a quotation.
03 9752 3766Supplied and supported locally by Novasys Group.
Start with the question your testing needs to answer. Are batches changing in lightness? Does a coating hide its backing? Has a surface cleaning process made a measurable difference?
Tell Novasys about your material, sample preparation and acceptance criteria. We can help you assess whether the Novo-Shade Duo+ fits your process and which supporting test materials you need.
Agree a repeatable preparation and measurement procedure before comparing production results.
Compare reflected light on a black-to-white scale. This is a lightness check, rather than a full colour measurement.
Measure a sample over white and black backings to assess how effectively it hides the substrate.
Compare a clean tape reference with tape used to collect debris from the test surface.

For coatings, use an appropriate black-and-white opacity chart, control the applied film and allow it to dry before testing. For other materials, agree how the sample will sit over the two backings.
Ask Novasys about the instrument, suitable charts and film application equipment together, so the quotation reflects your complete test process.
Explore Leneta test chartsFeatured instrument: Novo-Shade Duo+
45/0° reflectometry.
| Geometry | 45/0° |
|---|---|
| Measurement spot | 15 × 10 mm ellipse |
| Resolution | 0.1 |
| Repeatability | 0.2% |
| Reproducibility | 0.5% |
| Battery | Rechargeable lithium-ion |
| Typical operation | 17+ hours; 20,000+ readings per charge |
| Recharge time | 4 hours using mains charger |
| Memory | 8 MB; up to 999 readings |
| Data transfer | USB and Bluetooth |
| Operating conditions | 15–40°C; up to 85% RH, non-condensing |
| Dimensions | 65 × 140 × 50 mm (H × W × D) |
| Unit weight | 790 g |
| Order code | A4000-010 |
Specifications are from the manufacturer’s product information. Confirm the current instrument configuration and performance requirements with Novasys.
Describe your materials and testing objective so we can discuss a suitable procedure.
Shade and opacity have different meanings, even when displayed on a 0–100 scale. In cleanliness mode, the scale describes change against a reference; a higher number is not a “cleaner surface” score.
Record the mode, reference material and sample preparation with your results. Contact Novasys if you need help establishing the procedure.
Full instrument features and performance details.
Open datasheet ManualSetup, calibration and mode-specific guidance.
Open manual ManufacturerAdditional manufacturer information and application notes.
Visit RhopointSpeak with your local Novasys team about selection, sample preparation and support.
No. It uses 45/0° reflectometry for shade, opacity and cleanliness checks. If your requirement is gloss, ask Novasys to compare instruments from the Rhopoint glossmeter range.
Shade mode provides a greyscale lightness comparison. It does not replace full spectral colour measurement when your process needs to distinguish hue or manage colour formulation. Tell us what you need to control so we can discuss the appropriate instrument.
You need an agreed sample preparation method and suitable black and white backings. For coating tests, include the opacity chart, film application method and drying requirements in your discussion with Novasys.
The manufacturer describes a tape comparison procedure using a clean reference and tape that has collected debris from the test surface. Follow the product manual and keep tape, backing and handling consistent.
The instrument supports stored readings and data transfer. Discuss your mode, batching and reporting requirements with Novasys, because available functions vary between modes.
Use the product enquiry pop-up or call Novasys Group, a Rhopoint Instruments distribution partner in Australia. Include your materials, test objective and quantities, plus charts or accessories you need.