60° remote head
Reach suitable small, curved and recessed measurement areas.
Product viewManufacturer photography · Select a thumbnail to explore. Adaptors shown are application-dependent; confirm your supplied configuration with Novasys.
Bring gloss measurement to small, curved and difficult-to-reach surfaces. A lightweight remote head and dedicated low-gloss scale help you check finishes that are challenging for a conventional instrument.
Ask Novasys about suitability, accessories and a quotation.
03 9752 3766Supplied and supported locally by Novasys Group.
A finished component may have a small test area, a curved profile or a location that a standard glossmeter cannot reach. Start with the actual part and the finish you need to control.
Send Novasys sample photographs, dimensions and your test requirements. We can help you assess the Flex 60 and discuss suitable measuring adaptors.
Define a consistent test location and handling procedure before comparing samples or batches.
Reach suitable small, curved and recessed measurement areas.
GUh provides 0.01 GU equivalent resolution for low-gloss finishes.
Discuss standard, magnetic steel-surface and custom positioning options.
Review statistics, graphs and pass/fail limits, then transfer results for reporting.

A suitable adaptor helps locate the head on the intended area. For formed parts, define the contact points, orientation and handling method as part of your testing procedure.
Discuss your sample geometry with Novasys before selecting the setup. A smaller or curved part still needs to be assessed for measurement suitability.
Featured model: Novo-Gloss Flex 60
60° remote-head measurement geometry.
| Gloss angle | 60° |
|---|---|
| GU range / resolution | 0–125 GU / 0.1 GU |
| GU repeatability / reproducibility | ±0.2 GU / ±0.5 GU |
| GUh range | 0–125 GUh, equivalent to 0–12.5 GU |
| GUh resolution | 0.1 GUh, equivalent to 0.01 GU |
| GUh repeatability / reproducibility | ±0.5 GUh / ±2.0 GUh |
| Measurement area | 6 × 12 mm |
| Standards | ISO 2813, ASTM D523, ASTM D2457, DIN 67530, JIS 8741, JIS K 5600-4-7 |
| Battery | Rechargeable lithium-ion; 14,000 readings per charge |
| Memory | 8 MB; up to 2,950 readings |
| Data transfer | USB and Bluetooth |
| Operating conditions | 15–40°C; up to 85% RH, non-condensing |
| Instrument dimensions / weight | 80 × 150 × 35 mm (H × W × D) / 392 g |
| Head dimensions / weight | 60 × 110 × 28 mm (H × W × D) / 109 g |
| Order code | A4000-020.2 |
Specifications shown are for Novo-Gloss Flex 60. The GUh low-gloss scale is not available on Flex 60-X. Refer to the current manufacturer datasheet for performance conditions.
Tell us about your samples and acceptance criteria so we can help you assess suitability.
This page features Novo-Gloss Flex 60, with its additional GUh low-gloss scale and interchangeable measuring adaptors.

Custom adaptors are application-dependent. Confirm the part geometry and measurement setup with Novasys.
Detailed specifications and product features.
Open datasheet ManualSetup, calibration and operating guidance.
Open manual ManufacturerAdditional manufacturer product information.
Visit RhopointSpeak with your local Novasys team about product selection and support.
This page features Flex 60. It includes the additional GUh low-gloss scale and interchangeable measuring adaptors. Flex 60-X is a different configuration. Ask Novasys to confirm the model and supplied accessories before ordering.
It provides finer resolution for low-gloss surfaces. On the Flex 60, 0.1 GUh corresponds to 0.01 GU. Record the scale used with your results so readings are interpreted correctly.
No. Novo-Gloss Flex 60 measures gloss at 60°. For reflection haze, DOI or RIQ requirements, ask Novasys to compare the Rhopoint IQ range.
Suitability depends on sample geometry, available area and how the head is positioned. Provide photographs, dimensions and the intended test location so we can discuss a suitable approach.
Yes. Tell us about the shape, material and finish of the part, and where the measurement needs to be taken. Novasys can discuss the information needed to assess a custom adaptor.
Use the product enquiry pop-up or call Novasys Group, a Rhopoint Instruments distribution partner in Australia. We can discuss the instrument, adaptors, documentation and ongoing calibration requirements together.
Tell us what you test. We’ll help you plan the next step.