Four-terminal input
Separate current and voltage paths minimise the contribution of test-lead resistance.
Product & caseManufacturer photography · Select a thumbnail to explore the meter and spring clip leads. Optional probe leads are quoted separately.
Measure low resistance with a compact digital meter built for one-handed use. The M210 combines four-terminal Kelvin connections, automatic ranging and a low 5 mA test current for checks on contacts, components and connections.
Ask Novasys about your application, lead options and a quotation.
03 9752 3766Supplied and supported locally by Novasys Group.
Test leads can contribute a significant error when measuring very low resistance. M210 uses separate current and voltage connections to reduce that influence and measure the resistance at the test points.
The low test current also helps avoid electrically cleaning a contact during measurement, an effect that can change the result when higher currents are used. Discuss the contact type and test requirements with Novasys before selecting the method.
Automatic ranging and decimal-point selection keep the interface simple for routine checks.
Separate current and voltage paths minimise the contribution of test-lead resistance.
A maximum 5 mA current helps preserve the contact condition during the test.
Press ON to measure. The meter selects its range and switches off automatically after three minutes.
A single 9 V PP3-type battery provides around 20 hours of continuous use, according to Rhopoint.

One wire pair carries the meter’s test current. The other pair measures the voltage drop across the component. The meter calculates resistance from the current and voltage.
The supplied spring clips provide separate electrical contacts in each jaw, allowing a four-wire connection with two clips. Good contact at both faces remains important for stable readings.
Featured model: M210
UKAS calibration certificate configuration.
| Measurement ranges | 1.999 Ω, 19.99 Ω and 199.9 Ω |
|---|---|
| Range increments | 0.001 Ω, 0.01 Ω and 0.1 Ω respectively |
| Accuracy | ±0.1% of range |
| Zero offset | ±0.001 Ω |
| Maximum test current | 5 mA |
| Maximum voltage | 1.4 V |
| Temperature drift | 0.013%/°C of lowest range |
| Display | 3½-digit LCD |
| Range selection | Automatic |
| Automatic power-off | After 3 minutes |
| Battery | 9 V PP3, MN1604 or equivalent |
| Continuous operation | Approximately 20 hours with standard PP3 battery |
| Operating temperature | 5–35°C |
| Weight including case & leads | 510 g |
| Dimensions in case (H × W × D) | 150 × 145 × 45 mm |
| Dimensions out of case (H × W × D) | 150 × 80 × 38 mm |
Specifications follow Rhopoint’s M210 product information. Accuracy is specified as a percentage of range. Confirm suitability, required resolution and calibration documentation with Novasys.
Start with the expected resistance, access to the test points and your required test method.
Lead selection depends on how you can reach and contact the component.

Spring clip leads are included. A replacement set can be requested separately.
Measurement ranges, specifications and lead information.
Open datasheet ManufacturerFurther details for the UKAS calibration certificate configuration.
Open manufacturer Local supportDiscuss lead options, calibration and service requirements.
Explore supportSpeak with your local Novasys team about product selection and support.
The meter has three automatically selected ranges: 1.999 Ω, 19.99 Ω and 199.9 Ω. Their respective increments are 0.001 Ω, 0.01 Ω and 0.1 Ω. The finest increment of 0.001 Ω is equivalent to 1 mΩ.
Separate wire pairs carry the test current and measure the voltage drop. This reduces the influence of lead resistance, which can be significant when the component resistance is very low.
Rhopoint explains that higher test currents can clean a contact electrically and change its measured resistance. The M210 uses a low 5 mA current to help retain the contact condition during testing.
Yes. The manufacturer configuration referenced on this page includes a UKAS calibration certificate, along with the meter, spring clip test leads, protective case and instructions. Confirm your required calibration scope and documentation with Novasys.
Spring clip leads are standard. The probe and contact connector lead set, part B210-110, is an optional extra. Replacement spring clip leads can also be requested.
Use the product enquiry pop-up or call Novasys Group, a Rhopoint Instruments distribution partner in Australia. Include the expected resistance range, component type, lead access and calibration requirements.
Tell us what you test. We’ll help you plan the next step.