Rhopoint InstrumentsSmall & curved surfaces · Remote head

IQ Flex 2020° Gloss, Haze & DOI Meter

Bring appearance measurement to small, curved and difficult-to-reach surfaces. A compact remote head helps you assess gloss, haze and reflected image clarity on finished parts.

20° glossHaze · DOI · RIQRemote head
  • Reach small areas and non-flat components
  • Assess more than gloss alone
  • Discuss adaptors for your sample geometry
Featured configurationIQ Flex 20Order code: A6000-016

Ask Novasys about suitability, accessories and a quotation.

03 9752 3766
Your Australian distribution partner

Supplied and supported locally by Novasys Group.

Product datasheet & manual
Local expertise Australian application adviceProduct selection Instrument & accessory supportOngoing support Calibration & repair enquiries
Measure the part you actually make

Appearance testing
for less accessible surfaces.

Large, flat test panels are useful references, but a finished component can present a different measurement challenge. Start with the area you need to test, the curvature and the finish you need to control.

Novasys can help you assess the IQ Flex 20, compare adaptor options and plan a repeatable measurement approach for your samples.

More information from your finish

Look beyond a single gloss reading.

Use appearance measurements to investigate the finish differences that matter to your product and your customers.

20° gloss

Measure high-gloss finishes with a compact remote measuring head.

Haze & image clarity

Assess reflectance haze, DOI and RIQ alongside gloss.

Access to small parts

Bring the measuring head to areas a conventional instrument cannot easily reach.

Application adaptors

Match the contact and spot size to your sample geometry.

Rhopoint IQ Flex 20 remote head taking a measurement on a curved surface
Match the setup to the sample

Curvature matters.
So does positioning.

Repeatable results depend on the sample and how the measuring head is located. A reduced spot does not automatically make every small or curved part suitable for testing.

Send Novasys photographs, dimensions and a description of the area you need to measure. We can discuss adaptor selection and the appropriate next step.

Technical details

IQ Flex 20 specifications

Featured model: IQ Flex 20
20° remote-head measurement geometry.

Measurement & instrument specifications
Gloss angle20°
Gloss range0–2,000 GU
Gloss resolution0.1 GU
Standard measurement area6 × 6.4 mm
Gloss repeatability0–100 GU: 0.2 GU; 100–2,000 GU: 0.2%
Gloss reproducibility0–100 GU: 0.5 GU; 100–2,000 GU: 0.5%*
DOI / RIQ range0–100
RSPEC range0–2,000 GU
Haze unitsHU or LogHU; 0.1 HU resolution
Haze / DOI standardASTM E430
BatteryRechargeable lithium-ion
Typical operation6 hours; 4,000+ readings per charge
Recharge time4 hours using mains charger
Memory8 MB; up to 999 readings
Dimensions, excluding head150 × 79 × 34 mm (H × W × D)
Weight550 g
Order codeA6000-016

* A mirror gloss calibration standard is required to achieve the stated high-range reproducibility. Refer to the current manufacturer datasheet for full performance conditions.

Applications

What finish do you need to check?

Tell us about your samples and acceptance criteria so we can help you assess suitability.

Configure your measurement head

Choose the adaptor around your part.

Discuss standard, reduced-spot, curved-part and custom positioning options before selecting your setup.

Rhopoint IQ Flex 20 interchangeable measuring adaptors

Adaptor suitability varies with sample geometry and finish. Recalibrate when changing adaptors, following the manufacturer’s procedure.

Product resources

Datasheet, manual & manufacturer information.

Before you enquire

IQ Flex 20 FAQs

Speak with your local Novasys team about product selection and support.

How does IQ Flex 20 differ from the standard Rhopoint IQ?

IQ Flex 20 uses a compact remote measuring head for access to small and curved parts. The standard IQ has a different instrument format. Tell Novasys about your samples so we can help you compare the options.

Does IQ Flex 20 measure at 60° or 85°?

No. IQ Flex 20 uses a 20° geometry. Ask Novasys if your test method requires other angles or if you are comparing readings from existing equipment.

Can it measure any curved surface?

Suitability depends on curvature, part size, finish and adaptor selection. Send sample photographs, dimensions and the intended test location so we can discuss a suitable approach.

Which adaptor should I choose?

Start with the size and shape of the area you need to measure. Reduced-spot, curved-part and custom options serve different applications. Confirm the adaptor and calibration procedure with Novasys before ordering.

What information is needed for a custom adaptor?

Provide a DXF drawing of the part, clear photographs and a marked measurement location. Include your finish type and the appearance properties you need to control.

How do I request pricing and Australian support?

Use the product enquiry button or call Novasys Group, a Rhopoint Instruments distribution partner in Australia. We can discuss the instrument, adaptors, calibration requirements and quotation details together.

Your Australian Rhopoint distribution partner

Bring appearance control
to your finished parts.

Tell us what you test. We’ll help you plan the next step.

Or call 03 9752 3766
Explore the full Rhopoint range
Local knowledge. Practical advice.

Enquire about IQ Flex 20.

Tell us about your samples and testing requirements. Our Australian team will help you confirm suitability, accessories and quotation details.

03 9752 3766info@novasys.com.au

This opens your email app with your enquiry ready to send.