Water-duty design
Compare configurations for cooling- and hot-water applications.
Product viewManufacturer imagery and technical resources. Product view is representative; supplied configuration depends on your application.
Rotary joints for cooling- and hot-water service in plastics, textiles and paper equipment. DX combines pressure-loaded mechanical seals with one- or two-way flow arrangements and replaceable seal components.
Ask Novasys about configuration and a quotation.
03 9752 3766Product advice and enquiries through Novasys Group.
DX rotary joints are used for water transfer into rotating equipment, including textile, plastics and paper applications. Their pressure-loaded mechanical seals use media pressure to support seal closing force.
One- and two-way versions provide different flow layouts. Novasys can help compare the connection arrangement, temperature, pressure and speed against your existing joint or new installation.
Compare configurations for cooling- and hot-water applications.
The mechanical seal uses pressure to reinforce closing force.
One- and two-way versions support different supply and return arrangements.
A replaceable rotor seal simplifies service of the appropriate assembly.

DXS and DXSB are specific designs within the wider range. The manufacturer describes a metal-ceramic coating for DXS and a supported inner tube for the DXSB design.
Send the complete type code and suffixes so Novasys can check the actual design, required wear parts and replacement details. Similar appearance alone does not establish compatibility.
Confirm the exact type and duty before ordering.
| Media listed by manufacturer | Cooling water and hot water |
|---|---|
| Published pressure maximum | 16 bar in the product overview; confirm the exact operating envelope |
| Published temperature maximum | 160°C; subject to type, seals and operating conditions |
| Published speed expression | 5,500 / nominal width; confirm units, size and applicable catalogue limits for the exact joint |
| Flow arrangement | One-way or two-way versions |
| Housing | Brass; manufacturer identifies cast iron from nominal size 100 |
| Rotor material | Stainless steel |
| Mechanical seal | Pressure-loaded design |
| Bearing lubrication | Factory-lubricated rolling bearings; maintenance-free description is qualified to operation up to 80°C |
| DXS variant | Metal-ceramic coating for specified difficult applications |
| DXSB variant | Inner tube supported in the slider |
| Service feature | Replaceable rotor mating ring |
The overview values are selection guidance, not a combined operating guarantee. Confirm the exact variant, media conditions, allowable speed and lubrication instructions before ordering.
For replacement or repair enquiries, include the full DX, DXS or DXSB designation, any suffix, nameplate photographs and dimensions. Add the operating medium, pressure, temperature and rotational speed.
Novasys can discuss the required technical information, replacement identification and spare-part options. Confirm compatibility and current availability for the specific assembly.
Practical advice on selection and local support.
The manufacturer DX page lists cooling water and hot water. If your duty uses another medium, ask Novasys to review the application rather than assuming a standard DX is suitable.
The manufacturer qualifies its maintenance-free bearing description to operation up to 80°C. Higher temperatures and specific variants need the applicable operating and lubrication instructions.
The manufacturer identifies a metal-ceramic coating for DXS and an inner tube supported in the slider for DXSB. Confirm the complete type designation to establish the design and required parts.
The page publishes these as series overview maxima. They do not establish an allowable combined duty. Confirm pressure, temperature, speed and the exact variant against the current catalogue and manufacturer advice.
A change to DS needs a configuration check. Modified or adapted DX/DXS units require individual assessment. Send the full type code, suffixes and dimensions so Novasys can discuss the options.
Use the product enquiry or call Novasys. Include the water temperature, pressure, speed, flow rate, connection size and flow arrangement. For an existing unit, add clear nameplate and installation photographs.
Send the operating and connection details. We’ll help with the next step.